WhatsApp Chat

Biofeedback Nerve and Muscle Stimulator SKYKM-560

1,664.00 $

Key Features

  • EMG biofeedback therapy
  • Neuromuscular electrical stimulation (NMES)
  • Electrical Trigger Stimulation (ETS)
  • 7-inch TFT LCD touchscreen
  • Real-time EMG waveform display
  • Interactive EMG gaming exercises
  • Multi-channel treatment technology
  • Adjustable stimulation intensity (0–99)
  • Patient database management
  • Treatment record storage and retrieval
  • Report printing software support
  • Pelvic floor rehabilitation programs
  • Postpartum recovery programs

SKYKM-560 Biofeedback Nerve and Muscle Stimulator

The  SKYKM-560 is an advanced rehabilitation system that integrates EMG biofeedback therapy, neuromuscular electrical stimulation (NMES), electrical trigger stimulation (ETS), and interactive training programs into a single professional device.

Designed for hospitals, physiotherapy clinics, rehabilitation centers, pelvic floor therapy practices, and women’s health specialists, the SKYKM-560 helps improve neuromuscular control, restore muscle function, and support rehabilitation through real-time biofeedback and stimulation technologies.


Advanced Biofeedback Rehabilitation Technology

The SKYKM-560 combines:

  • Surface EMG biofeedback assessment
  • Neuromuscular electrical stimulation (NMES)
  • Electrical Trigger Stimulation (ETS)
  • Interactive EMG game training
  • Pelvic floor rehabilitation programs
  • Postpartum recovery training

This integrated approach allows therapists to objectively assess muscle activity while providing targeted stimulation and functional training.


7-Inch Touchscreen Interface

The large 7-inch TFT LCD display provides:

  • Real-time EMG waveform display
  • Treatment data monitoring
  • Visual training feedback
  • Easy touch-screen navigation
  • User-friendly treatment setup

The intuitive interface simplifies operation for clinicians and therapists.


EMG Assessment Functions

Standard Pelvic Floor Assessment

Provides comprehensive evaluation of pelvic floor muscle activity and function.

Quick Surface EMG Assessment

Fast measurement and analysis of muscle electrical activity.

EMG Value Analysis

  • Detects muscle activation levels
  • Compares results with preset reference values
  • Assists treatment planning
  • Tracks rehabilitation progress

EMG Biofeedback Training

The SKYKM-560 uses real-time muscle electrical activity as physiological feedback.

Training feedback options include:

  • Interactive graphics
  • Visual displays
  • Voice guidance
  • EMG gaming exercises
  • Multimedia rehabilitation programs

These features improve patient engagement and training effectiveness.


Electrical Trigger Stimulation (ETS)

ETS mode combines voluntary muscle activation with electrical stimulation.

How it works:

  1. Device detects muscle activity.
  2. EMG activity is compared to preset thresholds.
  3. Electrical stimulation automatically activates when the threshold is reached.

This method promotes active participation and neuromuscular re-education.


Neuromuscular Electrical Stimulation (STIM)

The stimulation module provides electrical therapy through preset and customizable programs.

Available Modes

  • 8 preset stimulation programs
  • 1 custom stimulation mode
  • 14 postpartum recovery programs

Intensity levels can be adjusted according to patient tolerance and rehabilitation goals.


Multi-Channel Therapy

The SKYKM-560 supports:

  • 2-channel EMG assessment
  • 2-channel or 4-channel stimulation therapy

Multiple treatment channels allow simultaneous rehabilitation of different muscle groups and tissue areas.


EMG Game Training Programs

EMG Feedback Training

Includes programs for:

  • Explosive strength training
  • Endurance training
  • Combined power and endurance training

Interactive Scene Training

Features:

  • Slow muscle training
  • Fast muscle training
  • Daily activity simulation
  • Biological scene training
  • Specialized pelvic floor rehabilitation scenarios

These programs encourage patient participation and improve motor control training.


Patient Data Management

Built-in patient database allows:

  • Patient file creation
  • Patient record modification
  • Record deletion
  • Treatment history storage
  • Progress tracking

Historical treatment data can be reviewed at any time.


Report Generation

Using PC software, clinicians can:

  • Analyze EMG results
  • Generate assessment reports
  • Print patient reports
  • Monitor rehabilitation progress

Ideal for clinical documentation and patient follow-up.


Clinical Applications

Suitable for rehabilitation and treatment of:

  • Pelvic floor dysfunction
  • Urinary incontinence
  • Postpartum rehabilitation
  • Neuromuscular dysfunction
  • Stroke rehabilitation
  • Cerebrovascular accident recovery
  • Muscle weakness
  • Motor dysfunction disorders
  • Functional rehabilitation training
  • Pain management programs

Key Features

  • EMG biofeedback therapy
  • Neuromuscular electrical stimulation (NMES)
  • Electrical Trigger Stimulation (ETS)
  • 7-inch TFT LCD touchscreen
  • Real-time EMG waveform display
  • Interactive EMG gaming exercises
  • Multi-channel treatment technology
  • Adjustable stimulation intensity (0–99)
  • Patient database management
  • Treatment record storage and retrieval
  • Report printing software support
  • Pelvic floor rehabilitation programs
  • Postpartum recovery programs

Technical Specifications

Specification Details
Model SKYKM-560
Brand Konmed
Display 7-inch TFT LCD Touchscreen
EMG Channels 2 Channels
Stimulation Channels 2 or 4 Channels
Intensity Range 0–99
EMG Assessment Standard & Quick Evaluation
ETS Function Yes
EMG Game Training Yes
Patient Database Yes
Report Printing Supported via PC Software
Therapy Modes EMG, ETS, STIM, Biofeedback
Applications Pelvic Floor, Neurological & Musculoskeletal Rehabilitation

Package Includes

  • SKYKM-560 Main Unit
  • Patient Cables
  • Stimulation Accessories
  • Power Supply
  • User Manual